ASTM E205-96(2022)
(Specification)Standard Specification for Glass and Oxygen Combustion Flask
Standard Specification for Glass and Oxygen Combustion Flask
ABSTRACT
This specification covers the design and dimensional requirements for flasks and closures, with a fixed platinum sample holder, used in the original oxygen-flask combustion procedures.
SCOPE
1.1 This specification covers the flask and closure, with a fixed platinum sample holder, used in the original oxygen-flask combustion procedures (1, 2).2
Note 1: This specification was originally developed by the Committee on Microchemical Apparatus, Division of Analytical Chemistry, American Chemical Society (3). Specifications for types of apparatus that utilize electric (2, 4-7) or infrared (8) ignition are not included because of lack of experience with these.
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
General Information
- Status
- Published
- Publication Date
- 31-Dec-2021
- Technical Committee
- E41 - Laboratory Apparatus
- Drafting Committee
- E41.01 - Laboratory Ware and Supplies
Relations
- Effective Date
- 01-Jul-2019
- Effective Date
- 01-Nov-2013
- Effective Date
- 01-Dec-2011
- Effective Date
- 01-Dec-2011
- Effective Date
- 01-Sep-2010
- Effective Date
- 15-May-2010
- Effective Date
- 01-Nov-2008
- Effective Date
- 01-Nov-2006
- Effective Date
- 01-Oct-2005
- Effective Date
- 01-Jan-2000
- Effective Date
- 01-Jan-2000
- Effective Date
- 10-Nov-1997
- Effective Date
- 10-Nov-1997
- Effective Date
- 10-Oct-1996
- Effective Date
- 01-Jan-1996
Overview
ASTM E205-96(2022): Standard Specification for Glass and Oxygen Combustion Flask defines the requirements for glass flasks and closures equipped with a fixed platinum sample holder, intended for use in original oxygen-flask combustion procedures. Developed by ASTM International, this specification ensures quality and safety in laboratory applications where combustion analysis is performed to determine the presence of specific elements, such as halogens or sulfur, in organic substances. The document details both design and dimensional requirements, strictly using SI units, to promote consistency across laboratories worldwide.
Key Topics
- Material Specifications: The combustion flasks and their closures must be made of borosilicate glass, providing high resistance to thermal shock and chemical corrosion.
- Platinum Sample Holder: All closures specified are supplied with a fixed platinum sample holder, which is essential for supporting the sample during combustion under an oxygen atmosphere.
- Standard Sizes: The primary standard flask sizes outlined are 300 mL and 500 mL. Larger sizes, such as 1000 mL and 2000 mL, are also used in some specialized analyses, particularly for tissue samples.
- Safety Precautions: The specification underscores the importance of laboratory safety measures-including the use of gloves, goggles, and shields-when handling oxygen combustion flasks.
- Scope Limitations: The standard applies exclusively to flasks employing traditional ignition methods. Apparatus utilizing electric or infrared ignition are excluded from this specification due to insufficient industry experience.
Applications
ASTM E205-96(2022) is widely used in analytical chemistry labs for precise microanalysis, particularly in:
- Elemental Analysis: Determining the presence and quantity of halogens, sulfur, and other elements in organic or biological materials via oxygen-flask combustion.
- Research and Quality Control: Supporting protocols in research institutions, academic laboratories, and industrial settings where accurate chemical analysis is required.
- Standardized Testing: Providing laboratories with a common reference for equipment, ensuring compatibility and repeatability of results across different testing facilities.
The standard’s strict design criteria facilitate safe and reliable operation, making glass oxygen combustion flasks fundamental in processes that mandate rigorous analytical precision.
Related Standards
Several other ASTM standards work in conjunction with ASTM E205-96(2022) to cover various aspects of laboratory apparatus and analytical processes, including:
- ASTM E920: Specification for commercially packaged laboratory apparatus, ensuring safe and suitable packaging for transport and storage.
- ASTM E921: Specification for export packaging of laboratory apparatus, aimed at international shipping requirements.
- ASTM E1133: Practice for performance testing of packaged laboratory apparatus, with a focus on equipment intended for United States government procurement.
- ASTM E1157: Specification for sampling and testing reusable laboratory glassware, ensuring the reliable performance of glass analytical equipment during repeated use.
Practical Value
Complying with ASTM E205-96(2022) guarantees that laboratories utilize glass and oxygen combustion flasks designed for maximum safety, durability, and analytical reliability. By adhering to these detailed specifications, organizations promote high standards of laboratory practice, increase confidence in analysis results, and support regulatory compliance within the field of analytical chemistry.
Keywords: ASTM E205, glass laboratory flask, oxygen combustion flask, platinum sample holder, combustion analysis, halogen determination, sulfur analysis, borosilicate glass, analytical chemistry standard.
Buy Documents
ASTM E205-96(2022) - Standard Specification for Glass and Oxygen Combustion Flask
Get Certified
Connect with accredited certification bodies for this standard

ECOCERT
Organic and sustainability certification.

Eurofins Food Testing Global
Global leader in food, environment, and pharmaceutical product testing.

Intertek Bangladesh
Intertek certification and testing services in Bangladesh.
Sponsored listings
Frequently Asked Questions
ASTM E205-96(2022) is a technical specification published by ASTM International. Its full title is "Standard Specification for Glass and Oxygen Combustion Flask". This standard covers: ABSTRACT This specification covers the design and dimensional requirements for flasks and closures, with a fixed platinum sample holder, used in the original oxygen-flask combustion procedures. SCOPE 1.1 This specification covers the flask and closure, with a fixed platinum sample holder, used in the original oxygen-flask combustion procedures (1, 2).2 Note 1: This specification was originally developed by the Committee on Microchemical Apparatus, Division of Analytical Chemistry, American Chemical Society (3). Specifications for types of apparatus that utilize electric (2, 4-7) or infrared (8) ignition are not included because of lack of experience with these. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ABSTRACT This specification covers the design and dimensional requirements for flasks and closures, with a fixed platinum sample holder, used in the original oxygen-flask combustion procedures. SCOPE 1.1 This specification covers the flask and closure, with a fixed platinum sample holder, used in the original oxygen-flask combustion procedures (1, 2).2 Note 1: This specification was originally developed by the Committee on Microchemical Apparatus, Division of Analytical Chemistry, American Chemical Society (3). Specifications for types of apparatus that utilize electric (2, 4-7) or infrared (8) ignition are not included because of lack of experience with these. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM E205-96(2022) is classified under the following ICS (International Classification for Standards) categories: 71.040.20 - Laboratory ware and related apparatus. The ICS classification helps identify the subject area and facilitates finding related standards.
ASTM E205-96(2022) has the following relationships with other standards: It is inter standard links to ASTM E920-97(2019), ASTM E920-97(2013), ASTM E1157-87(2011), ASTM E1157-87(2018)e1, ASTM E1133-86(2010), ASTM E921-97(2010), ASTM E920-97(2008), ASTM E1157-87(2006), ASTM E1133-86(2005), ASTM E1133-86(2000), ASTM E1133-86(1996)e1, ASTM E920-97(2003), ASTM E921-97(2003), ASTM E1157-87(1996), ASTM E920-97. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
ASTM E205-96(2022) is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: E205 −96 (Reapproved 2022)
Standard Specification for
Glass and Oxygen Combustion Flask
This standard is issued under the fixed designation E205; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope E921 Specification for Export Packaged Laboratory Appa-
ratus
1.1 This specification covers the flask and closure, with a
E1133 Practice for Performance Testing of Packaged Labo-
fixed platinum sample holder, used in the original oxygen-flask
2 ratory Apparatus for United States Government Procure-
combustion procedures (1, 2).
ments
NOTE 1—This specification was originally developed by the Committee
E1157 Specification for Sampling and Testing of Reusable
on MicrochemicalApparatus, Division ofAnalytical Chemistry,American
Laboratory Glassware
Chemical Society (3). Specifications for types of apparatus that utilize
electric (2, 4-7) or infrared (8) ignition are not included because of lack of
3. Combustion Flasks
experience with these.
3.1 Combustion flasks shall be of borosilicate glass and
1.2 The values stated in SI units are to be regarded as
shall conform to the requirements shown in Fig. 1 for the 300
standard. No other units of measurement are included in this
and 500-ml sizes, respectively.
standard.
1.3 This international standard was developed in accor-
NOTE 2—Larger flasks (1000 and 2000-ml sizes) have been used,
particularly when analyses are done on tissue.
dance with internationally recognized principles on standard-
ization established in the Decision on Principles for the
4. Flask Closure
Development of International Standards, Guides and Recom-
mendations issued by the World Trade Organization Technical 4.1 Theflaskclosure,thatisusedwitheithersizeflask,shall
be of borosilicate glass and shall be provided with a fixed
Barriers to Trade (TBT) Committee.
platinum sample holder and shall conform to the requirements
2. Referenced Documents
shown in Fig. 1. Warning—Although broad usage has shown
2.1 ASTM Standards: oxygen flask combustion to be generally safe, precautions,
E920 Specification for Commercially Packaged Laboratory
such as use of gloves, goggles, shields, and so forth, should be
Apparatus taken when using these flasks for this purpose.
5. Sampling and Testing
This specification is under the jurisdiction of ASTM Committee E41 on
Laboratory Apparatus and is the direct responsibility of Subcommittee E41.01 on
5.1 Refer to Specification E1157.
Laboratory Ware and Supplies.
Current edition approved Jan. 1, 2022. Published February 2022. Originally
approvedin1962.Lastpreviouseditionapprovedin2016asE205 – 96(2016).DOI: 6. Packaging
10.1520/E0205-96R22.
6.1 Select from one of Specification E920, Specification
The boldface numbers in parentheses refer to the list of references appended to
this specification. E921, or Practice E1133.
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
7. Keywords
Sta
...




Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...