Standard Test Methods for Measuring Water Vapor Transmission Rate (WVTR) of Pharmaceutical Bottles and Blisters

SIGNIFICANCE AND USE
5.1 The purpose of these test methods is to obtain reliable values for WVTR that can be used to discriminate among barrier packages for pharmaceutical products. These test methods will establish a WVTR value that represents the water vapor transmission of the container closure system being evaluated. They are intended for use in evaluating or comparing, or both, the water vapor barrier performance of alternative packages for use in packaging of pharmaceutical products.  
5.2 While these methods were developed for a specific, limited application, they should be suitable for most types and sizes of consumer packages.
SCOPE
1.1 The three test methods described herein are for measurement of water vapor transmission rates (WVTRs) of high-barrier multiple-unit containers (bottles), high-barrier single-unit containers (blisters), and quasi-barrier single-unit containers used for packaging pharmaceutical products. The containers are tested closed and sealed. These test methods can be used for all consumer-sized primary containers and bulk primary containers of a size limited only by the dimensions of the equipment and the weighing capacity and sensitivity of the balance.  
1.2 These test methods are intended to be of sufficient sensitivity and precision to allow clear discrimination among the levels of barrier packages currently available for pharmaceutical products.  
1.3 There are three methods: Method A is for bottles, Method B is for formed barrier blisters, and Method C is for formed quasi-barrier blisters. Methods B and C can be adapted for use with flexible pouches.  
1.4 These test methods use gravimetric measurement to determine the rate of weight gain as a result of water vapor transmission into the package and subsequent uptake by a desiccant enclosed within the package. The packages are exposed to environments typical of those used for accelerated stability testing of drug products in the package (typically 40 °C/75 % relative humidity [RH]).  
1.5 For these methods, balance sensitivity, amount of desiccant, number of blisters per test unit, and weighing frequency were developed in an experiment based on Test Methods E96/E96M.  
1.6 Test Methods E96/E96M gives specific instruction on the interactions among weighing frequency, number of data points necessary to establish steady state, minimum weight gain in a weighing period, and balance sensitivity.  
1.7 The test methods in this standard were developed specifically for pharmaceutical bottles and blisters as closed container-closure systems. The experiment from which the methods were developed provided an inter-laboratory study from which the precision and bias statement was written. The packages in the study were small bottles and blisters used regularly for pharmaceutical solid oral dosage forms.  
1.8 In spite of the specific nature of their application, the test methods in this standard should be suitable for other pharmaceutical packages and most types and sizes of other consumer packages.  
1.9 The values stated in SI units are to be regarded as the standard. No other units of measurement are included in this standard. The units of measure for bottles are milligrams per bottle per day (mg/bottle-day) and for blisters, milligrams per blister cavity per day (mg/cavity-day). These units may be used for both standard and referee testing.  
1.10 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.11 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Bar...

General Information

Status
Historical
Publication Date
31-Jul-2017
Drafting Committee
Current Stage
Ref Project

Buy Standard

Standard
ASTM D7709-12(2017) - Standard Test Methods for Measuring Water Vapor Transmission Rate (WVTR) of Pharmaceutical Bottles and Blisters
English language
7 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM D7709-12(2017) - Standard Test Methods for Measuring Water Vapor Transmission Rate (WVTR) of Pharmaceutical Bottles and Blisters
English language
7 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: D7709 − 12 (Reapproved 2017)
Standard Test Methods for
Measuring Water Vapor Transmission Rate (WVTR) of
Pharmaceutical Bottles and Blisters
This standard is issued under the fixed designation D7709; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 1.7 The test methods in this standard were developed
specifically for pharmaceutical bottles and blisters as closed
1.1 The three test methods described herein are for mea-
container-closure systems. The experiment from which the
surement of water vapor transmission rates (WVTRs) of
methods were developed provided an inter-laboratory study
high-barrier multiple-unit containers (bottles), high-barrier
from which the precision and bias statement was written. The
single-unit containers (blisters), and quasi-barrier single-unit
packages in the study were small bottles and blisters used
containers used for packaging pharmaceutical products. The
regularly for pharmaceutical solid oral dosage forms.
containers are tested closed and sealed. These test methods can
be used for all consumer-sized primary containers and bulk 1.8 In spite of the specific nature of their application, the test
primary containers of a size limited only by the dimensions of methods in this standard should be suitable for other pharma-
the equipment and the weighing capacity and sensitivity of the ceutical packages and most types and sizes of other consumer
balance. packages.
1.2 These test methods are intended to be of sufficient 1.9 The values stated in SI units are to be regarded as the
sensitivity and precision to allow clear discrimination among standard. No other units of measurement are included in this
the levels of barrier packages currently available for pharma- standard. The units of measure for bottles are milligrams per
ceutical products. bottle per day (mg/bottle-day) and for blisters, milligrams per
blister cavity per day (mg/cavity-day). These units may be used
1.3 There are three methods: Method A is for bottles,
for both standard and referee testing.
Method B is for formed barrier blisters, and Method C is for
1.10 This standard does not purport to address all of the
formed quasi-barrier blisters. Methods B and C can be adapted
safety concerns, if any, associated with its use. It is the
for use with flexible pouches.
responsibility of the user of this standard to establish appro-
1.4 These test methods use gravimetric measurement to
priate safety, health and environmental practices and deter-
determine the rate of weight gain as a result of water vapor
mine the applicability of regulatory limitations prior to use.
transmission into the package and subsequent uptake by a
1.11 This international standard was developed in accor-
desiccant enclosed within the package. The packages are
dance with internationally recognized principles on standard-
exposed to environments typical of those used for accelerated
ization established in the Decision on Principles for the
stability testing of drug products in the package (typically
Development of International Standards, Guides and Recom-
40 °C ⁄75 % relative humidity [RH]).
mendations issued by the World Trade Organization Technical
1.5 For these methods, balance sensitivity, amount of
Barriers to Trade (TBT) Committee.
desiccant, number of blisters per test unit, and weighing
frequency were developed in an experiment based on Test
2. Referenced Documents
Methods E96/E96M.
2.1 ASTM Standards:
1.6 Test Methods E96/E96M gives specific instruction on
E96/E96M Test Methods for Water Vapor Transmission of
the interactions among weighing frequency, number of data
Materials
points necessary to establish steady state, minimum weight
gain in a weighing period, and balance sensitivity.
3. Terminology
3.1 Definitions:
These test methods are under the jurisdiction of ASTM Committee F02 on
Primary Barrier Packaging and is the direct responsibility of Subcommittee F02.10
on Permeation. For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Current edition approved Aug. 1, 2017. Published August 2017. Originally contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
approved in 2011. Last previous edition approved in 2012 as D7709 – 12. DOI: Standards volume information, refer to the standard’s Document Summary page on
10.1520/D7709-12R17. the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
D7709 − 12 (2017)
3.1.1 barrier blister, n—blister made from high-barrier containers (or cards). The desiccant-filled blister card is stored
material, formed and sealed so that the water vapor transmis- in an environment at 40 °C ⁄75 % RH. The card of desiccant
sion rate (WVTR) (when tested at 40 °C ⁄75 % RH) is less than filled blisters is weighed at prescribed time intervals until
1.0 mg/cavity-day. steady-state weight gain is obtained. Once steady-state is
obtained, the blister cards are weighed at five consecutive time
3.1.2 blister, n—formed, lidded and sealed plastic dome that
points.
contains the solid oral product (usually one unit).
3.1.2.1 Discussion—Synonymous with cavity.
4.3 WVTR for Method A or B is calculated using linear
regression of the weight versus time. The number of blisters
3.1.3 card, n—contiguous group of blisters formed and
tested depends on the barrier characteristics of the material, the
sealed with lid in place.
size of the blister, and the sensitivity of the balance used in the
3.1.3.1 Discussion—The card is a production geometry that
test.
is a convenient quantity for a dosage regimen. The number of
blisters per card commonly ranges from one to ten but may be
4.4 4.4 In Method C for quasi-barrier blisters, desiccant is
more. From a marketing and production point of view, the card
placed in the blister and the lid material is sealed in place using
is the basic, irreducible number of blisters in a market or
equipment that is capable of correctly filling and sealing the
clinical trial package. The blister card may sometimes be
containers (or cards). The desiccant-filled blister card is stored
referred to as the container.
in an environment at 40 °C ⁄75 % RH. The desiccant-filled
blister card is weighed at zero time and 48 h (two days). At this
3.1.4 cavity, n—see blister.
time, the difference in weight (the weight gain) in mg/cavity-
3.1.5 container, n—(1) bottle that contains multiple units of
day is taken as the WVTR. The number of blisters tested
drug product, or (2) a card of blisters formed and sealed with
depends on the barrier characteristics of the material, the size
lid.
of the blister, and the sensitivity of the balance used in the test.
3.1.6 quasi-barrier blister, n—blister made from low-barrier
NOTE 1—For this test method, the requirement of five consecutive
materials formed and sealed so that the WVTR (when tested at
weighings is waived because the desiccant quickly becomes saturated
40 °C ⁄75 % RH) is greater than 1.0 mg/cavity-day.
when packed in a quasi-barrier package and stored at 40 °C ⁄75 % RH.
3.1.6.1 Discussion—An example of this is 250 µm (10 mil)
During development of this test method, it appeared that after the second
poly(vinyl chloride) (PVC) formed into size zero blisters and day the weight gain displayed a curvilinear profile typical of approaching
saturation of the desiccant. To obtain five weighings within two days is an
sealed with aluminum foil lid.
unwieldy process and is likely to lack precision.
3.1.7 test specimen (or specimen), n—(1) for bottles, the
bottle is the test specimen and (2) for blisters, the blister card 5. Significance and Use
is the test specimen.
5.1 The purpose of these test methods is to obtain reliable
3.1.7.1 Discussion—For blisters, more than one card (or
values for WVTR that can be used to discriminate among
specimen) may be grouped into a test unit for conducting the
barrier packages for pharmaceutical products. These test meth-
test.
ods will establish a WVTR value that represents the water
3.1.8 test unit, n—(1) for bottles, the bottle is the test unit as
vapor transmission of the container closure system being
well as being the test specimen and (2) for blisters, the test unit evaluated. They are intended for use in evaluating or
is a group of test specimens (cards) processed together for
comparing, or both, the water vapor barrier performance of
temperature and humidity exposure and weighing at each time alternative packages for use in packaging of pharmaceutical
point.
products.
3.1.8.1 Discussion—The purpose of the test unit for blisters
5.2 While these methods were developed for a specific,
is to gain the advantage of additive weight gain resulting from
limited application, they should be suitable for most types and
more blisters than are on a single card. Detailed discussion of
sizes of consumer packages.
this point is available in Test Methods E96/E96M. The term
test unit when applied to bottles is simply to maintain congru-
6. Apparatus
ence of naming among the three test methods.
6.1 For weighing the test units in Method A, use a balance
that has sufficient capacity to weigh the total of bottle, cap, and
4. Summary of Test Method
desiccant throughout the period of the test. The balance shall
4.1 In Method A for bottles, desiccant is placed in the bottle
have sensitivity adequate to measure small differences in
which is then closed in the normal manner including any weight from one time point to the next. The balance sensitivity
membrane (tamper-evident or otherwise) sealed in place. The
shall be smaller than 5 % of the differences in weight from one
desiccant-filled bottle is stored in an environment at 40 °C ⁄75 time point to the next. (For example, during development of
% RH. The desiccant-filled bottle is weighed at prescribed time
this test method, a balance with capacity of 110 g and
intervals until steady-state weight gain is obtained. Once sensitivity of 0.1 mg was found to be acceptable for a 60 CC
steady state is obtained, the bottles are weighed at five
bottle.)
consecutive time points.
6.2 For weighing the test specimens in Methods B and C,
4.2 In Method B for barrier blisters, desiccant is placed in use a balance that has sufficient capacity to weigh the closed,
the blister and the lid material is sealed in place using sealed blister test unit throughout the period of use. The
equipment that is capable of filling and properly sealing the balance shall have sensitivity adequate to measure small
D7709 − 12 (2017)
TABLE 1 Closing Torque for Screw-Type Containers
differences in weight from one time interval to the next. The
balance sensitivity shall be smaller than 5 % of the differences Suggested Tightness
Suggested Tightness
Closure Range with Manually
in weight from one time interval to the next. For example,
Range with Manually
A
Diameter, mm Applied Torque, in. ·
Applied Torque, N · m
during development of this method, a balance with capacity of
lbf
8 0.56 5
110 g and sensitivity of 0.1 mg was found to be acceptable.
10 0.68 6
Test Methods B and C may require that the blister cards
13 0.90 8
(containers) be bundled in multiples to achieve periodic weight
15 0.56 – 1.02 5 – 9
gains of sufficient magnitude to use the balance sensitivity. 18 0.79 – 1.13 7 – 10
20 0.90 – 1.36 8 – 12
When so bundled, these cards are called test units. Test
22 1.02 – 1.58 9 – 14
Methods E96/E96M specify that the weight gain in each
24 1.13 – 2.03 10 – 18
28 1.36 – 2.37 12 – 21
weighing period shall be 20 times the sensitivity of the balance.
30 1.47 – 2.60 13 – 23
6.3 For exposure of packages to the test environment for
33 1.69 – 2.82 15 – 25
38 1.92 – 2.94 17 – 26
Methods A, B, and C, use a chamber capable of maintaining 40
43 1.92 – 3.05 17 – 27
6 2 °C and 75 6 5 % RH. The humidification should be
48 2.15 – 3.39 19 – 30
achieved with de-ionized water, or equivalent means, to limit
53 2.37 – 3.39 21 – 30
58 2.60 – 4.52 23 – 40
contamination from water impurities.
63 2.82 – 4.86 25 – 43
66 2.94 – 5.08 26 – 45
7. Reagents and Materials
A
For a closure having diameter between two diameters listed, use the torque range
7.1 Purity of Reagents—Reagent-grade chemicals shall be
for the next larger diameter.
used in all tests. Unless otherwise indicated, it is intended that
all reagents conform to the specifications of the Committee of
Analytical Reagents of the American Chemical Society where
such specifications are available. Other grades may be used,
bottles for preparation at the time of testing. The bottles and
provided it is first ascertained that the reagent is of sufficiently
closures should be stored such that they will not be damaged;
high purity to permit its use without lessening the accuracy of
particularly the mating surfaces of bottle and closure. Prepare
the determination.
the test specimens by filling each bottle ⁄3 with desiccant then
7.2 Desiccant for Method A—During development of close the container in the appropriate manner as quickly as
Method A, anhydrous calcium chloride in granular form was
possible, including any membrane seal (tamper-evident or
used as the desiccant. Other desiccants may be suitable; for otherwise), if appropriate. Filling of bottles shall be done in a
example, a molecular sieve or silica gel. If calcium chloride in
low-humidity atmosphere (as low as possible, but not greater
any form, including anhydrous, is used it shall be pre-dried at
than 50 % RH). Close screw caps in accordance with the torque
1 1
215 6 5 °C for 7 ⁄4 6 ⁄4 h to ensure that any hexahydrate
recommendations in Table 1.
present is fully converted to the anhydrate. Cool the desiccant
8.2 Methods B and C (Blisters)—Fill with pre-dried desic-
in a desiccator for at least 2 h before use.
cant and seal the blisters on equipment that is capable of
NOTE 2—It has been shown that anhydrous calcium chloride may
correctly filling and sealing the market or clinical trial package.
contain calcium hexahydrate, which loses water only when the tempera-
The desiccant tablet should fill the cavity, but for practical
ture reaches 200 °C.
considerations, multiple fragments may be used. If fragments
7.3 Desiccant for Methods B and C—During development
are used, the total weight of desiccant shall be enough to meet
of Method B, silica gel was used as the desiccant. It was used
the quantity required to avoid partial saturation of the desiccant
in a molded form to fit the size and shape of the blister used.
before completion o
...


This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: D7709 − 12 D7709 − 12 (Reapproved 2017)
Standard Test Methods for
Measuring Water Vapor Transmission Rate (WVTR) of
Pharmaceutical Bottles and Blisters
This standard is issued under the fixed designation D7709; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 The three test methods described herein are for measurement of water vapor transmission rates (WVTRs) of high-barrier
multiple-unit containers (bottles), high-barrier single-unit containers (blisters), and quasi-barrier single-unit containers used for
packaging pharmaceutical products. The containers are tested closed and sealed. These test methods can be used for all
consumer-sized primary containers and bulk primary containers of a size limited only by the dimensions of the equipment and the
weighing capacity and sensitivity of the balance.
1.2 These test methods are intended to be of sufficient sensitivity and precision to allow clear discrimination among the levels
of barrier packages currently available for pharmaceutical products.
1.3 There are three methods: Method A is for bottles, Method B is for formed barrier blisters, and Method C is for formed
quasi-barrier blisters. Methods B and C can be adapted for use with flexible pouches.
1.4 These test methods use gravimetric measurement to determine the rate of weight gain as a result of water vapor transmission
into the package and subsequent uptake by a desiccant enclosed within the package. The packages are exposed to environments
typical of those used for accelerated stability testing of drug products in the package (typically 40°C/7540 °C ⁄75 % relative
humidity [RH]).
1.5 For these methods, balance sensitivity, amount of desiccant, number of blisters per test unit, and weighing frequency were
developed in an experiment based on Test Methods E96/E96M.
1.6 Test Methods E96/E96M gives specific instruction on the interactions among weighing frequency, number of data points
necessary to establish steady state, minimum weight gain in a weighing period, and balance sensitivity.
1.7 The test methods in this standard were developed specifically for pharmaceutical bottles and blisters as closed
container-closure systems. The experiment from which the methods were developed provided an inter-laboratory study from which
the precision and bias statement was written. The packages in the study were small bottles and blisters used regularly for
pharmaceutical solid oral dosage forms.
1.8 In spite of the specific nature of their application, the test methods in this standard should be suitable for other
pharmaceutical packages and most types and sizes of other consumer packages.
1.9 The values stated in SI units are to be regarded as the standard. No other units of measurement are included in this standard.
The units of measure for bottles are milligrams per bottle per day (mg/bottle-day) and for blisters, milligrams per blister cavity
per day (mg/cavity-day). These units may be used for both standard and referee testing.
1.10 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety safety, health and healthenvironmental practices and determine the
applicability of regulatory limitations prior to use.
1.11 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ThisThese test method ismethods are under the jurisdiction of ASTM Committee F02 on FlexiblePrimary Barrier Packaging and is the direct responsibility of
Subcommittee F02.10 on Permeation.
Current edition approved May 1, 2012Aug. 1, 2017. Published June 2012August 2017. Originally approved in 2011. Last previous edition approved in 20112012 as
ε1
D 7709 – 11D7709 – 12. . DOI: 10.1520/D7709-12.10.1520/D7709-12R17.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
D7709 − 12 (2017)
2. Referenced Documents
2.1 ASTM Standards:
E96/E96M Test Methods for Water Vapor Transmission of Materials
3. Terminology
3.1 Definitions:
3.1.1 barrier blister, n—blister made from high-barrier material, formed and sealed so that the water vapor transmission rate
(WVTR) (when tested at 40°C/7540 °C ⁄75 % RH) is less than 1.0 mg/cavity-day.
3.1.2 blister, n—formed, lidded and sealed plastic dome that contains the solid oral product (usually one unit).
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
3.1.2.1 Discussion—
Synonymous with cavity.
3.1.3 card, n—contiguous group of blisters formed and sealed with lid in place.
3.1.3.1 Discussion—
The card is a production geometry that is a convenient quantity for a dosage regimen. The number of blisters per card commonly
ranges from one to ten but may be more. From a marketing and production point of view, the card is the basic, irreducible number
of blisters in a market or clinical trial package. The blister card may sometimes be referred to as the container.
3.1.4 cavity, n—see blister.
3.1.5 container, n—(1) bottle that contains multiple units of drug product, or (2) a card of blisters formed and sealed with lid.
3.1.6 quasi-barrier blister, n—blister made from low-barrier materials formed and sealed so that the WVTR (when tested at
40°C/7540 °C ⁄75 % RH) is greater than 1.0 mg/cavity-day.
3.1.6.1 Discussion—
An example of this is 250 μm (10 mil) poly(vinyl chloride) (PVC) formed into size zero blisters and sealed with aluminum foil
lid.
3.1.7 test specimen (or specimen), n—(1) for bottles, the bottle is the test specimen and (2) for blisters, the blister card is the
test specimen.
3.1.7.1 Discussion—
For blisters, more than one card (or specimen) may be grouped into a test unit for conducting the test.
3.1.8 test unit, n—(1) for bottles, the bottle is the test unit as well as being the test specimen and (2) for blisters, the test unit
is a group of test specimens (cards) processed together for temperature and humidity exposure and weighing at each time point.
3.1.8.1 Discussion—
The purpose of the test unit for blisters is to gain the advantage of additive weight gain resulting from more blisters than are on
a single card. Detailed discussion of this point is available in Test Methods E96/E96M. The term test unit when applied to bottles
is simply to maintain congruence of naming among the three test methods.
4. Summary of Test Method
4.1 In Method A for bottles, desiccant is placed in the bottle which is then closed in the normal manner including any membrane
(tamper-evident or otherwise) sealed in place. The desiccant-filled bottle is stored in an environment at 40°C/7540 °C ⁄75 % RH.
The desiccant-filled bottle is weighed at prescribed time intervals until steady-state weight gain is obtained. Once steady state is
obtained, the bottles are weighed at five consecutive time points.
4.2 In Method B for barrier blisters, desiccant is placed in the blister and the lid material is sealed in place using equipment
that is capable of filling and properly sealing the containers (or cards). The desiccant-filled blister card is stored in an environment
D7709 − 12 (2017)
at 40°C/7540 °C ⁄75 % RH. The card of desiccant filled blisters is weighed at prescribed time intervals until steady-state weight
gain is obtained. Once steady-state is obtained, the blister cards are weighed at five consecutive time points.
4.3 WVTR for MethodsMethod A or B is calculated using linear regression of the weight versus time. The number of blisters
tested depends on the barrier characteristics of the material, the size of the blister, and the sensitivity of the balance used in the
test.
4.4 4.4 In Method C for quasi-barrier blisters, desiccant is placed in the blister and the lid material is sealed in place using
equipment that is capable of correctly filling and sealing the containers (or cards). The desiccant-filled blister card is stored in an
environment at 40°C/7540 °C ⁄75 % RH. The desiccant-filled blister card is weighed at zero time and 48 h (two days). At this time,
the difference in weight (the weight gain) in mg/cavity-day is taken as the WVTR. The number of blisters tested depends on the
barrier characteristics of the material, the size of the blister, and the sensitivity of the balance used in the test.
NOTE 1—For this test method, the requirement of five consecutive weighings is waived because the desiccant quickly becomes saturated when packed
in a quasi-barrier package and stored at 40 °C ⁄75 % RH. During development of this test method, it appeared that after the second day the weight gain
displayed a curvilinear profile typical of approaching saturation of the desiccant. To obtain five weighings within two days is an unwieldy process and
is likely to lack precision.
NOTE 1—For this test method, the requirement of five consecutive weighings is waived because the desiccant quickly becomes saturated when packed
in a quasi-barrier package and stored at 40°C/75 % RH. During development of this test method, it appeared that after the second day the weight gain
displayed a curvilinear profile typical of approaching saturation of the desiccant. To obtain five weighings within two days is an unwieldy process and
is likely to lack precision.
5. Significance and Use
5.1 The purpose of these test methods is to obtain reliable values for WVTR that can be used to discriminate among barrier
packages for pharmaceutical products. These test methods will establish a WVTR value that represents the water vapor
transmission of the container closure system being evaluated. They are intended for use in evaluating or comparing, or both, the
water vapor barrier performance of alternative packages for use in packaging of pharmaceutical products.
5.2 While these methods were developed for a specific, limited application, they should be suitable for most types and sizes of
consumer packages.
6. Apparatus
6.1 For weighing the test units in Method A, use a balance that has sufficient capacity to weigh the total of bottle, cap, and
desiccant throughout the period of the test. The balance shall have sensitivity adequate to measure small differences in weight from
one time point to the next. The balance sensitivity shall be smaller than 5 % of the differences in weight from one time point to
the next. (For example, during development of this test method, a balance with capacity of 110 g and sensitivity of 0.1 mg was
found to be acceptable for a 60 CC bottle.)
6.2 For weighing the test specimens in Methods B and C, use a balance that has sufficient capacity to weigh the closed, sealed
blister test unit throughout the period of use. The balance shall have sensitivity adequate to measure small differences in weight
from one time interval to the next. The balance sensitivity shall be smaller than 5 % of the differences in weight from one time
interval to the next. (ForFor example, during development of this method, a balance with capacity of 110 g and sensitivity of 0.1
mg was found to be acceptable. Test Methods B and C may require that the blister cards (containers) be bundled in multiples to
achieve periodic weight gains of sufficient magnitude to use the balance sensitivity. When so bundled, these cards are called test
units. Test Methods E96/E96M specify that the weight gain in each weighing period shall be 20 times the sensitivity of the balance.
6.3 For exposure of packages to the test environment for Methods A, B, and C, use a chamber capable of maintaining 40 6
2°C2 °C and 75 6 5 % RH. The humidification should be achieved with de-ionized water, or equivalent means, to limit
contamination from water impurities.
7. Reagents and Materials
7.1 Purity of Reagents—Reagent-grade chemicals shall be used in all tests. Unless otherwise indicated, it is intended that all
reagents conform to the specifications of the Committee of Analytical Reagents of the American Chemical Society where such
specifications are available. Other grades may be used, provided it is first ascertained that the reagent is of sufficiently high purity
to permit its use without lessening the accuracy of the determination.
7.2 Desiccant for Method A—During development of Method A, anhydrous calcium chloride in granular form was used as the
desiccant. Other desiccants may be suitable; for example, a molecular sieve or silica gel. If calcium chloride in any form, including
1 1
anhydrous, is used it shall be pre-dried at 215 6 5°C5 °C for 7 ⁄4 6 ⁄4 h to ensure that any hexahydrate present is fully converted
to the anhydrate. Cool the desiccant in a desiccator for at least 2 h before use.
Reagent Chemicals, American Chemical Society Specifications, American Chemical Society, Washington, DC. For suggestions on the testing of reagents not listed by
the American Chemical Society, see Analar Standards for Laboratory Chemicals, BDH Ltd., Poole, Dorset, U.K., and the United States Pharmacopeia and National Formulary,
U.S. Pharmacopeial Convention, Inc. (USPC), Rockville, MD.
D7709 − 12 (2017)
NOTE 2—It has been shown that anhydrous calcium chloride may contain calcium hexahydrate, which loses water only when the temperature reaches
200 °C.
NOTE 2—It has been shown that anhydrous calcium chloride may contain calcium hexahydrate, which loses water only when the temperature reaches
200°C.
7.3 Desiccant for Methods B and C—During development of Method B, silica gel was used as the desiccant. It was used in a
molded form to fit the size and shape of the blister used. Other desiccants may be suitable, for example, a molecular sieve. If silica
1 1
gel is used, it shall be pre-dried in a circulating hot air oven at one of two conditions: 155 6 5°C5 °C for 3 ⁄4 6 ⁄4 h or 150 6
1 1 1 1
5°C5 °C for 4 ⁄4 6 ⁄4 h. Dry m
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.