ASTM ISO/ASTM51539-05(2013)
(Main)Standard Guide for Use of Radiation-Sensitive Indicators
Standard Guide for Use of Radiation-Sensitive Indicators
SIGNIFICANCE AND USE
4.1 Indicators may be used to show that products have been exposed to a radiation source. They should be used only to provide a qualitative indication of radiation exposure and may be used to distinguish processed loads that have been irradiated from unirradiated process loads.
NOTE 1—The use of indicators does not eliminate the need for other process-control procedures, such as quantitative dosimetry or the controlled segregation of irradiated from nonirradiated products.
NOTE 2—See ISO/ASTM Standards 51204, 51431, 51608, 51649, 51702, 51939, and 51940 for information on the use of indicators in the various types of processing facilities and for unique product applications.
4.2 The indicator manufacturer is obliged to supply a statement regarding the approximate dose level at which the examiner (20/20 vision), at standard illumination (unfiltered daylight, or artificial light of the spectrum and intensity defined by the proper ASTM standard), is able to determine the visual change in the indicator.
SCOPE
1.1 This guide covers procedures for using radiationsensitive indicators (referred to hereafter as indicators) in radiation processing. These indicators may be labels, papers, inks or packaging materials which undergo a visual change when exposed to ionizing radiation (1-5).2
1.2 The purpose for using indicators is to determine visually whether or not a product has been irradiated, rather than to measure different dose levels.
1.3 Indicators are not dosimeters and shall not be used as a substitute for proper dosimetry. Information about dosimetry systems for radiation processing is provided in other ASTM and ISO/ASTM documents (see ISO/ASTM Guide 51261).
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
ISO/ASTM 51539:2005 (Reapproved 2013)(E)
Standard Guide for
Use of Radiation-Sensitive Indicators
This standard is issued under the fixed designation ISO/ASTM 51539; the number immediately following the designation indicates the
year of original adoption or, in the case of revision, the year of last revision.
1. Scope (Bremsstrahlung) Irradiation Facilities for Food Process-
ing
1.1 This guide covers procedures for using radiation-
51608 Practice for Dosimetry in an X-ray (Bremsstrahlung)
sensitive indicators (referred to hereafter as indicators) in
Facility for Radiation Processing
radiation processing. These indicators may be labels, papers,
51649 Practice for Dosimetry in an Electron Beam Facility
inks or packaging materials which undergo a visual change
2 for Radiation Processing at Energies between 300 keV and
when exposed to ionizing radiation (1-5).
25 MeV
1.2 The purpose for using indicators is to determine visually
51702 Practice for Dosimetry in Gamma Facility for Radia-
whether or not a product has been irradiated, rather than to
tion Processing
measure different dose levels.
51939 Practice for Blood Irradiation Dosimetry
51940 Guide for Dosimetry for Sterile Insect Release Pro-
1.3 Indicators are not dosimeters and shall not be used as a
substitute for proper dosimetry. Information about dosimetry grams
systems for radiation processing is provided in other ASTM
2.3 International Commission on Radiation Units and Mea-
and ISO/ASTM documents (see ISO/ASTM Guide 51261).
surements (ICRU) Reports:
ICRU Report 85 Fundamental Quantities and Units for
1.4 This standard does not purport to address all of the
safety concerns, if any, associated with its use. It is the Ionizing Radiation
responsibility of the user of this standard to establish appro-
3. Terminology
priate safety and health practices and determine the applica-
bility of regulatory limitations prior to use.
3.1 Definitions:
3.1.1 dosimetry system—system used for determining ab-
2. Referenced documents
sorbed dose, consisting of dosimeters, measurement instru-
ments and their associated reference standards, and procedures
2.1 ASTM Standards:
for the system’s use.
E170 Terminology Relating to Radiation Measurements and
Dosimetry
3.1.2 indicator—see radiation-sensitive indicator.
2.2 ISO/ASTM Standards:
3.1.3 process load—volume of material with a specified
51204 Practice for Dosimetry in Gamma Irradiation Facili-
product loading configuration irradiated as a single entity.
ties for Food Processing
3.1.4 radiation-sensitive indicator—material such as coated
51261 Practice for Calibration of Routine Dosimetry Sys-
or impregnated adhesive-backed substrate, ink, coating or other
tems for Radiation Processing
materials which may be affixed to or printed on the process
51431 Practice for Dosimetry in Electron Beam and X-ray
loads, and which undergoes a visual change when exposed to
ionizing radiation.
3.1.4.1 Discussion—This visual change may be as observed
This guide is under the jurisdiction of ASTM Committee E61 on Radiation with the unaided eye or with an eye aid such as an optical filter.
Processing and is the direct responsibility of Subommittee E61.04 on Specialty
3.1.4.2 Discussion—In the past, radiation-sensitive indica-
Application, and is also under the jurisdiction of ISO/TC 85/WG 3.
tors have been referred to by different names (1-5) including
Current edition approved May 27, 2013. Published July 2013. Originally
ε1
label dosimeters, label indicators, indicator labels, dose
published as ASTM E 1539–93. Last previous ASTM edition E 1539–98 . ASTM
E 1539–93 was adopted by ISO in 1998 with the intermediate designation ISO
indicators, and radiation monitoring labels. ASTM Subcom-
15564:1998(E). The present International Standard ISO/ASTM
mittee E10.01 considers a label dosimeter to be fundamentally
51539:2005(2013)(E) replaces ISO 15544 and is a reapproval of the last previous
different from an indicator, and intends to define a label
edition ISO/ASTM 51539:2005(E).
The boldface numbers in parentheses refer to the bibliography at the end of this dosimeter as a type of routine dosimeter (that is, quantitative)
guide.
For referenced ASTM and ISO/ASTM standards, visit the ASTM website,
www.astm.org, or contact ASTM Customer Service at service@astm.org. For
Annual Book of ASTM Standards volume information, refer to the standard’s Available from the International Commission on Radiation Units and
Document Summary page on the ASTM website. Measurements, 7910 Woodmont Ave., Suite 800, Bethesda, MD 20814, USA.
© ISO/ASTM International 2023 – All rights reserved
ISO/ASTM 51539:2005 (2013)(E)
that is unique in that it is attached firmly to the product and can 5.6 Indicator materials may include, but are not limited to,
be read out without being removed from the product. coated or impregnated adhesive-backed substrates, inks and
coatings (1-5).
3.2 Definitions of other terms used in this standard that
pertain to radiation measurement and dosimetry may be found
6. Application
in ASTM Terminology E170. Definitions in ASTM E170 are
6.1 Indicators may be used to help ensure that the process
compatible with ICRU 85; that document, therefore, may be
load has been irradiated.
used as an alternative reference.
6.2 Indicators may be used to ensure segregation of irradi-
ated product from non-irradiated product within the radiation
4. Significance and use
processing facility.
4.1 Indicators may be used to show that products have been
6.3 In the event of interruption of the irradiation process,
exposed to a radiation source. They should be used only to
indicators attached to product may help to locate the specific
provide a qualitative indication of radiation exposure and may
zone of process interruption, thereby minimizing the amount of
be used to distinguish processed loads that have been irradiated
discarded product.
from unirradiated process loads.
6.4 Indicators may be used for monitoring multiple-sided
NOTE 1—The use of indicators does not eliminate th
...